AVF7000 Series

The LZN7000 Series is a Vortex Flowmeter based on  Von Karman theory of vortices generated by a bluff body in the pipe. The
number of vortices are linearly proportional to the volumetric flow in the pipe. The LZN7000 is versatile flowmeter widely used for Gases, Steam & Liquid applications. There are no moving parts and comes with either flange or wafer connection. Standard configuration has local indication for flowrate and total flow as well as 4-20 mA with HART signal and pulse output functions. The microprocessor design can filter out erroneous  signals as well as interfence caused by pipe vibration.

Category:
  • Simplified setup and self-diagnostic functions
  • Auto. Temperature & Pressure compensation
  • 4-20 mA with HART signal and pulse outputs, user selectable
  • A very wide selection of sizes
  • Wide temperature range up to 420 °C
  • Non-volatile memory for setup and calibration
Size : 15, 20, 25, 32, 40, 50, 65, 80, 100, 125,
150, 200, 250, 300, 350, 400, 450, 500 mm
Measuring Range : Steam -1.6~540,000 kg/hr
: Gas -3~46,000 m3/hr
: Liquid -0.3~4950 m3/hr
Material : Stainless Steel 301 / 304 / 316
Accuracy Liquid : +/-0.7% value of reading
Gas & Steam : +/-1.0% value of reading
Unit : Nm3/hr, Nm3/min, Nm3/s, m3/hr,
m3/min, m3/s, L/hr, L/min, L/s, t/d,
t/hr, t/min, kg/hr, kg/m, kg/s, USgal/min, UKgal/min, ft3/hr, Ib/hr, bbl/d
Repeatability : +/-0.2% value of reading
Process Connection : Flange / Wafer
Flange Type : JIS 10K / JIS 20K / JIS 40K
ANSI 150# / ANSI 300# / ANSI 600#
DIN PN10 / PN16 / PN25 / PN40
Wafer Type : DN40-DN250 without Temp. / Pressure Sensor
Temperature : -40~280 °C (Standard)
: -40~420 °C (Optional)
Ambient Temperature : -20~60 °C
Pressure : 78 kgf/cm2 (Max.)
Protection Class : IP65
: Intrinsically Safe, Eex ia IIC T4
: Explosion Proof, Ex d IIC T6
Local Display : 2 or 3 lines LCD
: 6 Digit flowrate
: 8 Digit Totalizer
Current Output : 4-20 mA (2 wires) with HART signal
Load : Rohm= (VDC-12) * 50
Pulse Output : Scaled Pulse
Load : 1000-5000 Ω
Communication : HART (Compatible)
or RS485 (MODBUS Protocol)
Data Storage : Operation parameter and totalizer
figures are stored by EEPROM for more
than 10 years
Housing Material : Aluminum Alloy
Cable Entry : Standard: M20 * 1.5 Option: 1/2″ NPTF
Power Supply : 12-32 VDC
: Ni-MH Battery (3 years working hours)
KeyPad : 3 Internal keys for programming
and display control
Option
Pressure Sensor : Pressure compensation
Signal Output : 0-30 m VDC (20 μA Power Supply)
Temperature Sensor : Temperature compensation
Signal Output : PT1000 (2 wires)