- Converter can be rotated at six directions for easy installation
- Can display flow rate, totalizer and differential pressure at the same time
- Two years stability of 0.2%
- 0.075% accuracy
- Parameter setting by keypad directly
- 4-20 mA and pulse output, HART communication
- Automatic zero calibration by press-button
- Explosion Proof and weather proof housing
| Process Fluid | : | Liquid, Gas, Vapor |
| Application | : | Differential pressure flow measurement |
| Pressure Range | : | 0-2500 kPa |
| Flow Range | : | 0-999999 |
| Turndown Ratio | : | 20:1 |
| Accuracy | : | +/-0.075% of span |
| Stability | : | +/-0.15% of URL for 2 years |
| Working Temperature | : | -25~95 °C |
| Max. Pressure | : | 40 MPa |
| Material | ||
| Flange / Adapter | : | Stainless Steel 304 / Stainless Steel 316 |
| Drains / Vents | : | Stainless Steel 304 / Stainless Steel 316 |
| Diaphragm | : | Stainless Steel 316L / Hastelloy B / |
| Hastelloy C / Monel / Tantalum | ||
| Wetted O-Ring | : | Buna N / Viton / PTFE |
| Bolts & Nuts | : | Carbon Steel / Stainless Steel 316 |
| Mounting Bracket | : | Carbon Steel / Stainless Steel 304 / 316 |
| Name / Tag Plate | : | Stainless Steel 304 / Stainless Steel 316 |
| Converter Housing | : | Low copper cast aluminum alloy with |
| polyurethane, light blue paint | ||
| Fill Fluid | : | Silicone Oil / Fluorine Oil |
| Protection Class | : | IP67 (Standard) |
| : | Intrinsically Safe, Eex ia IIC T5 (Standard) | |
| : | Explosion Proof, Ex d IIB T5 (Optional) | |
| Mounting | : | Direct Mounting / Bracket on 2″ Pipe |
| Display | : | 9-Digit totalizer, 6-Digit flow rate |
| Display Unit | : | 32 Flow engineering unit |
| 5 Digits programmable for special unit | ||
| Keypad | : | 3 Internal keys for programming |
| and output setting | ||
| Current Output | : | 4-20 mA (2 wires) |
| with HART signal (Compatible) | ||
| Load | : | Rohm= (VDC-9) * 50 |
| Pulse Output | : | Scaled Pulse |
| Power Supply | : | 9-36 VDC |
| Damping | : | 0-32 Seconds |
| Humidity Limit | : | 0-100% Relative Humidity |
| Turn on Time | : | 2 Seconds with minimum damping |
| Zero Calibration | : | Automatic zero calibration by press-button |
| Cable Entry | : | M20 Conduit Threads / 1/2″ NPT (Female) |
| Temperature Effect | : | +/-0.18% of span per 20 °C |
| Vibration Effect | : | +/-0.05% of URL per g to 200 Hz in any axis |
| EMI / RFI Effect | : | Follow SAMA PMC 33.1 from 20-1000 MHz |
| and for field strengths up to 30 V/m | ||
| Process Connection | : | 1/4-18 NPT |
| : | 1/2-14 NPT (with adapter) | |
| Ambient Temperature | : | -25~80 °C |
| Dimensions | : | 102 mm (W) * 188 mm (H) * 130 mm (D) |
| Weight | : | 3.5 kg |