- 4 line LCD to display flowrate, totalizer signal condition etc.
- The flowmeter is designed in high accuracy +/-1.0%
- Small sized (206 * 100 * 35 mm) light-weight (600 g)
- Wide range, Velocities (0.01~+/-32 m/s)
- Ni-MH Battery lasts for over 10 hours continuous operation
- Maximum temperature 160 °C
- Transducers for pipes size from 15-6000 mm (1/2″-240″)
- Built-in magnet in transducers, no need for steady tool on metal pipe
- Data logger which records flowrate, date, total flow, signal condition etc.
- Response time less than 1 second
| Measuring Principle | : | Transit time difference |
| Pipe Size | : | S Type: 15-100 mm (1/2″-4″) |
| : | M Type: 50-1000 mm (2″-40″) | |
| : | L Type: 300-6000 mm (12″-240″) | |
| : | HS Type: 15-100 mm (1/2″-4″) | |
| : | HM Type: 50-1000 mm (2″-40″) | |
| Pipe Material | : | Cast Iron, Stainless Steel, Ductile Iron |
| Copper, PVC, Aluminum, Asbestos | ||
| Fiberglass etc. | ||
| Liner Material | : | Tar Epoxy, Rubber, Mortar, Polypropylene, |
| Polystyrol, Polystyrene, Polyester, Ebonite, | ||
| Polyethylene, Teflon etc. | ||
| Display | : | 4 Line LCD with illumination |
| Flowrate | : | 5 Digit with decimal point |
| Totalizer | : | 8 Digit, Forward, Reverse & Net values |
| Engineer Unit | : | m3, Liter, US Gallon, Imperial Gallon, |
| Million Gallon, Cubic Feet, US Barrels, | ||
| Imperial Barrels, Oil Barrel | ||
| Time Unit | : | Second, Minute, Hour, Day |
| Other | : | Velocity, Date, Time, Signal condition |
| Accuracy | : | +/-1%~+/-2% value of reading (0.5-30 m/s) |
| : | +/-0.5% value of reading (Online calibration) | |
| Repeatability | : | +/-0.2% value of reading |
| Keypad | : | 18 Key with tactile action |
| Response Time | : | Less than 1 second |
| Flow Velocity | : | 0.01~+/-32 m/s |
| Resolution | : | 0.0001 m/s |
| Ambient Temperature | : | -40~60 °C |
| Ambient Humidity | : | 90% RH or Less |
| Built-in Battery | : | Ni-MH Battery |
| Operation Time | : | >10 Hours |
| Charger | : | 90-260 VAC 50/60 Hz, 8-12 h charging |
| Data Storage | : | Operation parameters and totalizer |
| figures are stored by EEPROM for more | ||
| than 10 years | ||
| Data Logger | : | Limitless overwriting in 64 columns |
| (Flowrate, totalizer, time, date included) | ||
| Alarm | : | High / Low with buzzer |
| Power Consumption | : | Less than 2W |
| Dimensions | : | 206 * 100 * 35 mm |
| Weight | : | 0.6 kg |
| Protection Class | ||
| Converter | : | IP65 |
| Sensor | : | IP65 (Standard) |
| : | IP68 (Submersible) |