LZN3500 Series

The LZN3500 series is a liquid turbine flowmeter, as fluid flows through turbine rotor and drives it to rotate, the rotating rotor periodically cuts magnetic field line to generate electric pulse signal, which can be transmitted to output and transferred to the meter to display flow rater or totalizer. It features in high accuracy, good repeatability, simple structure, low pressure loss, convenient maintenance, etc. It is ideal to measure the volume of low-viscosity liquids in closed pipes, such as tap and demineralised water, fuels, liquefied gases, light fuel oil, solvents, pharmaceutical fluids, food etc.

Category:
  • Designed for a wide range of liquid applications
  • High measuring accuracy, regardless of the mounting position
  • 4-20 mA with HART signal and pulse outputs, user selectable
  • Abrasion-resistant tungsten carbide rotor shaft and bearings
  • Superior materials of construction for high performance in aggressive environments
  • Easily cleaned and designed to flushed particulates through the turbine with the medium
  • For variable use thanks to different pick-up sensors as well as a variety of connections and sizes
Size : 6, 10, 15, 20, 25, 32, 40, 50, 65, 80,
100, 125, 150, 200 mm
Measuring Medium : Liquid
Max. Viscosity : 1-60 cSt
Measuring Range : 0.07-800 m3/hr
Accuracy : +/-1.0% of reading (Standrad)
: +/-0.5% of reading (Optional)
Repeatability : +/-0.2% of reading
Pressure Drop : Max. 290 mbar at 100% Measuring range
(Density 1 g/cm3, Viscosity 1cp)
Unit : m3/d, m3/hr, m3/m, m3/s, l/hr, l/m, l/s
t/d, t/hr, t/m, kg/d, kg/hr, kg/m, kg/s
g/hr, g/m, g/s
Material
Body : S.S. 304 / S.S. 316
Bearing : Tungsten nickel alloy
Rotor : S.S. 420 / S.S. 2205
Housing : Aluminum Alloy
: PA66 (Angular Connector)
Process Connection : Flange (DN6 – DN200)
: Thread (DN6 – DN50)
: Tri-Clamp (DN15 – DN80)
Max. Pressure : Flange: 63 kg/cm2
: Thread: 63 kg/cm2
: Tri-Clamp: 10 kg/cm2
Local Display : 2 or 3 lines LCD
: 6 Digit flowrate
: 8 Digit totalizer
Operation Temperature : -20~120 °C
Ambient Temperature : -20~60 °C
Current Output : 4-20 mA (2 wires)
Load : Rohm=(VDC-18) * 50
Pulse Output : Scaled Pulse / Unscaled Pulse
Load : 1000-5000 Ω
Communication : HART (Compatible)
: RS485 (MODBUS Protocol)
Data Storage : Operation parameter and totalizer figures
are stored by EEPROM ( >10 years)
Cable Entry : Standard: M20 Option: 1/2″ NPTF
: Angular Connector DIN EN 175301-803 A
Angular Connector
Ingress Protection : IP65
Wire Cross-section : Max. 1.5 mm2
Cable Diameter : 6-8 mm
Power Supply : 18-32 VDC / 18-26 VDC (without display)
: Ni-MH Battery (3 years working hours)
Protection Class : IP65 (Angular Connector)
: IP67 (Aluminum Alloy Housing)
: Explosion Proof, Ex d IIC T6
: Intrinsically Safe, Ex ia IIC T4